| Sign In | Join Free | My ecer.co.uk | 
 | 
Brand Name : TRAIRF
Place of Origin : Sichuan, China
MOQ : 1 Units
Price : USD 94.00-98.00 Pieces
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 5000 Pieces per 2-30days
Delivery Time : 2-30days
type : Laminar Flow Module
Frame : Aluminum / GI / SUS /MDF
Max Temperature : 70℃~150℃
Air supply direction : Top / Side
HEPA efficiency : 99.99% at 0.3um
Air Volume : 1000m³/h
Product Introduction:
The HEPA Terminal Box is the ideal terminal filtration device for thousands, thousands and 100,000 level purification air conditioning system, which can be widely used in the purification air conditioning system of medicine, health, electronics, chemical and other industries. The high efficiency air supply outlet is used as the terminal filtration device for the renovation and construction of 1000-300000 grade clean rooms, which is the key equipment to meet the purification requirements. The high efficiency air supply outlet includes a static pressure box, a diffuser plate, a high efficiency filter, and the interface of the air duct can be top connection or side connection.
Performance characteristics:
1. The housing is made of high quality cold rolled steel plate.
2. Electrostatic spraying on the surface.
3. Elegant appearance, compact structure, easy to install and maintain.
4. The outlet surface diffuser panel is aluminum spray, cold rolled steel spray or stainless steel.
Provisions:
(1) Clean air supply outlet should be attached to side supply by louvers, slit type tuyere; When the side flow is obstructed or the unit area is large, and the wind speed of the personnel activity area is strict, the side flow should not be used;
(2) When there is a suspended ceiling, the diffuser or orifice plate should be used for air supply according to the height of the air conditioning area and the requirements for air flow. When the air supply per unit area is large, and the wind speed or regional temperature difference in the personnel activity area is small, the orifice plate should be used for air supply;
(3) Spout air supply, swirling air supply or lower air supply should be used in tall Spaces;
(4) The variable air volume terminal device should ensure that the air distribution meets the basic requirements of the air conditioning area environment when the air volume changes;
(5) The surface temperature of clean air supply outlet should be higher than the indoor dew point temperature; Low temperature tuyere should be used when the indoor dew point temperature is lower.
|   | 
| 99.99% 0.3um HEPA Terminal Box FFU Fan Filter Unit 1000m³/h Images | 
 1000 CLASS Terminal HEPA Filter Air Duct Filter Box For Clean Room
                                                                                        
                                                        
                        
                        
                        
                                                            1000 CLASS Terminal HEPA Filter Air Duct Filter Box For Clean Room
                                                    
                        
                     0.3uM 99.99% HEPA Terminal Box Filter Diffuser 500m³/h
                                                                                        
                                                        
                        
                        
                        
                                                            0.3uM 99.99% HEPA Terminal Box Filter Diffuser 500m³/h
                                                    
                        
                     Air Purification System Laminar Flow Hepa Filter Box HEPA Terminal Box H13 H14
                                                                                        
                                                        
                        
                        
                        
                                                            Air Purification System Laminar Flow Hepa Filter Box HEPA Terminal Box H13 H14
                                                    
                        
                     OEM ODM HEPA Terminal Box Filter For Laboratory Clean Room
                                                                                        
                                                        
                        
                        
                        
                                                            OEM ODM HEPA Terminal Box Filter For Laboratory Clean Room
                                                    
                        
                     Industrial Air Conditioner With Air Handing Unit Ahu For Air Conditioning In
                                                                                    
                        
                        
                        
                                                            Industrial Air Conditioner With Air Handing Unit Ahu For Air Conditioning In
                                                    
                        
                     Box Filter Air Filter HEPA Terminal Box Diffuser For Clean Room
                                                                                        
                                                        
                        
                        
                        
                                                            Box Filter Air Filter HEPA Terminal Box Diffuser For Clean Room
                                                    
                        
                     Air Filter Fan Box With Centrifugal Fan For Cleaning Equipment
                                                                                    
                        
                        
                        
                                                            Air Filter Fan Box With Centrifugal Fan For Cleaning Equipment